Solar Ballast Weight Calculator
Ballast Weight Calculator
Calculate minimum ballast weight per module to resist wind uplift as per IS 875 Part 3. Adjust any input and the result updates live.
Inputs
Updates liveIS 875 gives none for solar arrays. Use the racking maker's wind-tunnel value; edge and corner rows see more uplift.
Coastal belt: 60 km wide on the east coast and the Gujarat coast (IS 875-3 clause 6.3.4). Post-cyclone importance: cyclone shelters, hospitals, schools, communication towers.
Results
LiveTotal ballast to resist wind uplift
100 modules · 596.5 kg / module
Design Wind
m/s
Uplift / Module
N
Ballast / Module
kg
Wind Load Breakdown
Before placing ballast, check 2.27 kN/m² against the roof's design capacity (Roof Load Check), with a structural engineer. Sliding is not checked here.
“IS 875 Part 3 (2015): Vz = Vb·k1·k2·k3·k4 and pz = 0.6·Vz², k2 at the roof height, k4 for the cyclone belt. The standard has no pressure coefficients for solar arrays: the uplift coefficient is an input. Ballast = pz × Cp × A × 1.5 / g (this calculator's safety factor). Sliding is not checked.”
About the Ballast Weight
Ballast weight calculation determines how much dead weight (concrete blocks, gravel, or pavers) is needed on a ballasted rooftop mounting system to resist wind uplift forces without penetrating the roof membrane — the key design challenge for flat-roof waterproof installations.
Last updated · How we build our calculators
Formula
Ballast per module (kg) = SF × Cp × pz × module area ÷ 9.81
- pz
- Design wind pressure from IS 875 Part 3: 0.6 × (Vb × k1 × k2 × k3 × k4)² (N/m²)
- Cp
- Net uplift coefficient — an input; IS 875 has none for solar arrays (default 1.3)
- SF
- Safety factor against uplift (1.5)
How to calculate it
- 1Compute the design wind pressure from IS 875 Part 3, with k2 at the roof height.
- 2Multiply by the net uplift coefficient and the module area for the uplift on each module.
- 3Ballast per module = 1.5 × uplift ÷ 9.81.
- 4Check the ballast's load on the roof against the roof's design capacity (Roof Load Check), with a structural engineer. Sliding is a separate check.
Worked example
Mumbai rooftop (Vb 44 m/s), 10 m high, terrain category 3: k2 = 0.91, so Vz = 40.0 m/s and pz = 962 N/m². With Cp 1.3 and a 2.583 m² module the uplift is 3,230 N, so ballast = 1.5 × 3,230 ÷ 9.81 = 494 kg per module. That is far more than ballasted systems carry: racking makers' wind-tunnel coefficients are usually much lower than 1.3, and their tested values should replace it.
What you can calculate
- IS 875 wind zone
- Uplift force
- Ballast kg
- Safety factor 1.5
Frequently asked questions
Can I use sand bags instead of concrete ballast?
Sand bags are sometimes used but are not recommended for permanent installations: they degrade in UV exposure, absorb water (increasing weight unpredictably), and may shift over time. Concrete or precast pavers are the standard ballast material — consistent density (2,300–2,500 kg/m³), UV-stable, and flat for even load distribution on the membrane.
How do I reduce ballast weight on a weak roof?
Three approaches: (1) lower the panel tilt angle — at 5–10° instead of 20°, wind uplift reduces significantly; (2) use aerodynamic low-drag mounting profiles designed to reduce the uplift coefficient; (3) switch to mechanically anchored mounting with fewer penetrations and seal carefully. Some manufacturers (Schletter, Esdec, K2) offer low-ballast aerodynamic systems that can reduce ballast requirements by 40–60%.
Ready to build your solar project?
Get free quotes from verified EPCs and installers across India.
You might also need
Pedestal Height
Calculate front and rear pedestal heights for target module tilt on flat rooftops
OpenModule Layout Planner
Plan tables, rows and string configuration for a rooftop array
OpenSetback from Parapet
Calculate minimum module setback from parapet walls to avoid shading
OpenWind Load (Rooftop)
Calculate uplift and lateral wind forces on rooftop PV modules per IS 875 Part 3
OpenAnchor Bolt Sizing
Check anchor bolt steel tension (IS 800) against factored wind uplift and count the bolts
OpenStructure Material BOQ
Estimate structural steel, channels, clamps and hardware quantities from module count
Open